Summary. Scan bodies link the implant to the CAD library, so their material affects fit. This guide compares titanium and PEEK: titanium is radiopaque, heat-resistant and dimensionally stable, while PEEK is flexible but can deform and is barely visible on X-ray. Two cases show mixed-material scan bodies failing, one leading to a bridge remake.

Introduction: the role of a scan body
A scan body has two jobs: it is a precise physical marker during scanning, and it is the link to the digital libraries in the lab. In the CAD software it is matched to its counterpart, which aligns the implant system's parts so the digital representation of the implant site is accurate. The material, mainly titanium or PEEK, therefore affects durability, accuracy and compatibility.
Benefits for the patient
- Precision and accuracy: a titanium scan body supports an accurate fit and alignment of the restoration.
- Reduced risk of errors: consistent performance lowers the risk of errors in the implant workflow.
Benefits for the practice
- Fewer complications: precise scan bodies reduce implant-related complications and follow-up issues.
- Versatility: titanium scan bodies are available for a wide range of implant systems.
- Precision and control: more predictable outcomes.
Titanium vs PEEK: a comparison
Titanium
- Durability: resists wear over time.
- Biocompatibility: compatible with human tissue.
- Precision: stable, with minimal distortion.
- Radiopacity: clearly visible on radiographs.
PEEK
- Flexibility: can be an advantage in specific clinical situations.
- Deformation risks: can deform if incorrectly positioned or exposed to high heat or certain chemicals.
- Limitations: less long-term durability, and little or no visibility on X-ray to confirm correct seating.
Summary
PEEK is flexible and light; titanium offers durability, precision and biocompatibility. The choice affects the longevity of the scan body and the success of the restoration.
Titanium and PEEK, side by side

Technical properties of titanium
- Corrosion resistance in the moist oral environment.
- Manufacturing precision, so each scan body matches the dental libraries predictably.
- Heat resistance during sterilisation, without deforming.
Radiopacity
Titanium on X-ray
A titanium scan body lets you confirm on X-ray not only that it is correctly seated but also that it is the correct scan body for the implant. The book's radiograph shows one scan body not properly seated and another with the incorrect connection.
PEEK on X-ray
PEEK has low radiopacity and is more or less invisible on X-ray, so position and connection cannot be confirmed.
Titanium
PEEK
Case studies
Part 1: poor visibility of a mixed-material scan body
A scan body combining PEEK and titanium was assessed on X-ray. The PEEK section was barely discernible compared with the titanium, which leaves uncertainty about whether the scan body is correctly positioned.
Part 2: detachment and a bridge remake
During an implant procedure the PEEK part of a mixed-material scan body detached from its titanium base when it hit the bone. The resulting misalignment meant the bridge did not fit and had to be remade.
Personal insights and recommendations
Przemek Seweryniak: "My preference has solidified over time towards titanium for scan bodies, a choice backed by both experience and results." The book names DESS Implants as an example of a manufacturer of titanium scan bodies.
Error reduction
Titanium scan bodies are stable and clearly visible on X-ray, which reduces the margin of error compared with PEEK, which may deform under stress. The book shows a DESS titanium scan body with a part number that shows up on scans from most intraoral scanners.
Compatibility with implant systems
Choose a supplier whose titanium scan bodies are compatible with many implant systems, so the clinic can work with different systems without compromising quality.
Conclusion
Based on experience, the book recommends titanium scan bodies for their precision, durability and radiopacity, and cautions against mixed-material scan bodies where radiographic verification matters. Related: All-on-X, Crowns and bridges, Rehabilitations, Surgical guides, why we use Grade 5 titanium and how to send digital impressions.
About the author
Przemek Seweryniak, CDT, graduated from the dental technician programme (Tandteknikerutbildningen) in Malmö in 1993 and founded Cosmodent AB in Malmö in 1998. He has worked with CAD/CAM since 2002 and with 3Shape since 2006, received the Sverker Toreskog Award in 2017, is a founding member and past president of the Swedish Academy of Cosmetic Dentistry and is ESCD certified.
Cosmodent · Guide
The full e-book, free
Download the complete PDF with every chapter, figure and clinical case.

From clinics that work with Cosmodent
“Dr. Ian Buckle, with over 30 years of experience in aesthetic and reconstructive dentistry, trusts Cosmodent to help him deliver exceptional results to his patients.”
— The Art of Smile Makeovers, Part One. Dr. Ian Buckle, Buckle Advanced Dental Care, works with Cosmodent
It is a physical marker during scanning that is matched to its counterpart in the CAD software, aligning the implant libraries so that the digital representation of the implant site is accurate.
According to the guide titanium is durable, corrosion-resistant, holds its shape during heat sterilisation and is clearly visible on X-ray. PEEK is flexible but can deform when incorrectly positioned or exposed to heat or certain chemicals.
A radiopaque titanium scan body lets you confirm on X-ray that it is fully seated and that the correct scan body is used for the implant. PEEK is more or less invisible on X-ray.
In the guide's cases the PEEK part was poorly visible on X-ray. In one case it detached from the titanium base when it hit bone, and the bridge had to be remade because of inadequate fit.